Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Braz. j. pharm. sci ; 48(2): 325-333, Apr.-June 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-643025

ABSTRACT

A simple flow-injection analysis procedure was developed for determining captopril in pharmaceutical formulations employing a novel solid-phase reactor containing silver thiocyanate immobilized in a castor oil derivative polyurethane resin. The method was based on silver mercaptide formation between the captopril and Ag(I) in the solid-phase reactor. During such a reaction, the SCN- anion was released and reacted with Fe3+, which generated the FeSCN2+ complex that was continuously monitored at 480 nm. The analytical curve was linear in the captopril concentration range from 3.0 × 10-4 mol L-1 to 1.1 × 10-3 mol L-1 with a detection limit of 8.0 × 10-5 mol L-1. Recoveries between 97.5% and 103% and a relative standard deviation of 2% for a solution containing 6.0 × 10-4 mol L-1 captopril (n = 12) were obtained. The sample throughput was 40 h-1 and the results obtained for captopril in pharmaceutical formulations using this procedure and those obtained using a pharmacopoeia procedure were in agreement at a 95% confidence level.


Um procedimento simples de análise por injeção em fluxo foi desenvolvido para a determinação de captopril em formulações farmacêuticas empregando um novo reator em fase sólida contendo tiocianato de prata imobilizado em resina poliuretana obtida a partir de óleo de mamona. O método foi baseado na formação de um mercapto composto de prata, no reator em fase sólida, obtido entre o captopril e Ag (I) imobilizada. Durante a reação, íons SCN- eram liberados e reagiam com Fe3+, gerando o complexo FeSCN2+, que foi continuamente monitorado em 480 nm. A curva analítica foi linear no intervalo de concentração de captopril entre 3,0 × 10-4 a 1,1 × 10-3 mol L-1 com um limite de detecção de 8,0 × 10-5 mol L-1. Recuperações entre 97,5-103% e desvio padrão relativo de 2% para uma solução contendo 6,0 × 10-4 mol L-1 de captopril (n = 12) foram obtidos. A frequência de amostragem foi de 40 h-1 e os resultados obtidos para captopril em formulações farmacêuticas utilizando este procedimento e o da Farmacopeia, estão de acordo em um nível de confiança de 95%.


Subject(s)
Captopril/pharmacokinetics , Chemistry, Pharmaceutical/classification , Flow Injection Analysis , Polyurethanes/classification
2.
Av. cardiol ; 31(1): 58-62, mar. 2011. ilus
Article in Spanish | LILACS | ID: lil-607766

ABSTRACT

La taquicardia ventricular incesante es una patología poco frecuente que habitualmente se presenta en pacientes con cardiopatía estructural, principalmente en aquellos con antecedentes de infarto al miocardio, sin embargo puede presentarse también en enfermos con miocardiopatía dilatada. La amiodarona puede controlar con éxito un 75% de los casos y en aquellos pacientes refractarios al tratamiento antiarrítmico la ablación por radiofrecuencia debe considerarse la terapia de primera elección.


Incessant ventricular tachycardia is a rare disorder that usually occurs in patients with structural heart disease, mainly in those with history of myocardial infarction, but may also occur in patients with dilated cardiomyopathy. Amiodarone can successfully treat 75% cases and in patients refractory to antiarrhythmic therapy, radiofrequency ablation should be considered first-line therapy.


Subject(s)
Humans , Female , Aged , Catheter Ablation/methods , Cardiomyopathy, Dilated/diagnosis , Tachycardia, Ventricular/pathology , Cardiology
SELECTION OF CITATIONS
SEARCH DETAIL